Browse Categories

Honeywell L8148A1017 High Limit Aquastat Relay

<< Previous in Honeywell Aquastats Next in Honeywell Aquastats >>
ratingratingratingratingrating
Price: $233.95
Item Number: L8148A1017
Manufacturer Name: Honeywell
Manufacturer Part No: L8148A1017

Honeywell L8148A1017 High Limit Aquastat Relay 
140 – 240 F range with 8 degree F fixed differential, low volt/millivolt

Overview

Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors.

Features

  • High limit opens burner circuit only.
  • Select models include transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 Vac thermostat with heat anticipator set at 0.2A.
  • TRADELINE models include well adapter, tube of heat conductive compound and range stops..
Specifications
  • Hazmat Information: UN 1294, TOLUENE, 3, II
  • Application: High Limit
  • Dimensions (in.): 4 5/16 in. high x 6 1/8 in. wide x 3 1/8 in. deep
  • Dimensions (mm): 110 mm high x 156 mm wide x 79 mm deep
  • Maximum Safe Operating Pressure (psi): Immersion Well: 255 psi
  • Maximum Safe Operating Pressure (kPa) Immersion Well: 1757 kPa
  • Temperature Range (F): Maximum--150 F with 1.2 A 24 V load; 77 F with 1.4 A 24 V load
  • Temperature Range (C): Maximum--66 C with 1.2 A 24 V load; 25 C with 1.4 A 24 V load
  • Mounting: Horizontal
  • Frequency: 60 Hz
  • Approvals, Underwriters Laboratories Inc.: UL Listed: File No. MP466, Vol. 13, Sec. 2, Guide No. MBPR2.
  • Approvals, CSA: Certified: File No. LR1620, Guide No. 400-E-O
  • Electrical Connections: Quick-Connect / Screw
  • Operating Humidity Range (% RH): 0 to 95% RH, non-condensing
  • Voltage: 120 Vac
  • Operating Temperature Range (F): High Limit-- 140 F to 240 F
  • Operating Temperature Range (C): High Limit-- 60 C to 116 C
  • Differential Temperature (F): 8 F fixed
  • Switching Action: SPST: High Limit & Circulator
  • Anticipator Setting: 0.2 A
  • Capillary Length (in.): 4 1/2 in.
  • Insulation Depth (in.): 1 1/2 in. to 3 in. less well
  • Insulation Depth (mm): 38 mm to 76 mm less well
  • Capillary Length (mm): 114 mm
  • Electrical Ratings, Burner: At Full Load-- Line Voltage: 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- Line Voltage: 44.4 A @ 120 Vac: 22.7 A @ 240 Vac; Millivolt--0.25 A @ 1/4 to 12 Vdc
  • Electrical Ratings, Circulator: At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac

Product Reviews

Rate This Product:
or Create a Review
(2 Ratings, 0 Reviews) Average Rating:
ratingratingratingratingrating
Shopping Cart
Your cart is empty.