Browse Categories

Honeywell S87D1004 2 Rod Direct Spark Ignition Control

<< Previous in Honeywell Pilots / Ignitors Next in Honeywell Pilots / Ignitors >>
Price: $286.18
Item Number: S87D1004
Manufacturer Name: Honeywell
Manufacturer Part No: S87D1004

Overview

Provide electronic control of direct spark ignition systems used on gas fire furnaces, boilers, and other heating appliances.

Features

  • Control ignition sequence and gas control operation.
  • Generate high voltage potential for main burner ignition.
  • Lockout after one trial for ignition if main burner fails to ignite.
  • Reset from thermostat after lockout.
  • Use modules (except S87C) with any combination gas control designed for direct spark applications and rated 2.0A or less.

Product Specifications

  • Dimensions (in.): 5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. long
  • Dimensions (mm): 133 mm high x 103 mm wide x 49 mm deep
  • Includes: Alarm terminal
  • Electrical Ratings: 24 Vac
  • Frequency: 60 Hz
  • Approvals, CSA: File 112491_0_000
  • Flame Failure Response Time (sec): 0.8 sec. @ 5.0 microamp
  • PrePurge: None
  • Ambient Temperature Range (F): -40 F to +175 F
  • Ambient Temperature Range (C): -40 C to +79 C
  • Ignition System Type: Direct Spark Ignition
  • Ignition Sequence: Single trial for main burner ignition (then shut down and lockout)
  • Typical Gas Control: VR8205, VR8305
  • Type of Gas: Natural or LP
  • Flame Sense: Two Rod
  • Ignition Source: Internal high voltage spark generator
  • Ignition Trials To Lockout: 1
  • Lockout Timing: 6 sec.
  • Ignition Trial Time (sec): 6 sec.
  • Maximum Valve Load @ 24 Vac (Amps): 2A
  • Typical Ignition Hardware: Q347A, Q354, Q366
  • Flame Failure Re-ignition Time (sec): 0.8 sec. maximum

Product Reviews

Rate This Product:
or Create a Review
(0 Ratings, 0 Reviews)
Shopping Cart