Large easy to read display in full size DMM; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
  • Large easy to read 2,000 count display
  • 0.5% DCV basic accuracy
  • 0 to 750 ACV; max resolution 1mV
  • 0 to 1,000 DCV; max resolution 0.1mV
  • 0 to 20M; max resolution 0.1
  • 0 to 10 amps AC/DC; max resolution 0.1uA
  • Data hold
  • cULus 61010-1
  • CAT II - 1000V, CAT III - 600V
  • 3 Year Limited Warranty
Specifications:
  • DC Volts/Amps:
    • Maximum Input: 1000V / 10A
    • Maximum Resolution: 0.1mV / 0.1 A
    • Accuracy: +/-0.5%
  • AC Volts/Amps:
    • Maximum Input: 750V / 10A
    • Maximum Resolution: 0.01mV / 0.1A
    • Accuracy: +/- 0.8% / +/-1%
  • Resistance (Ohms):
    • Maximum Input: 20M
    • Maximum Resolution: 0.1
    • Accuracy: +/-0.5%
  • Continuity: Audible at less than 100
  • Diode: 2.5V at 1mA maximum output
  • Data Hold
  • Protective Boot
  • Display Type: 2000 count LCD
  • Range Selection: Manual
  • Operating Temperature: 32F - 104F (0C - 40C)
  • Storage Temperature: 14F - 122F (-10C - 50C)
  • Humidity: 80% non-condensing
  • Size: 7.4" x 3.4" x 1.2" (187mm x 86mm x 33mm) with boot
  • Battery Type: 9V Alkaline (NEDA 1604)
  • Battery Life: 500hrs
  • Overvoltage Category: CAT III 600V
  • Agency Approval: cULus 61010-1, IEC 61010-1
  • Warranty: 3 Years
Applications:
  • Thermocouples in furnaces and gas appliances
  • Heat anticipator current in thermostats
  • Line and control voltages
  • Flame safety control current
  • Heating element resistance
  • Continuity of wiring
  • Line current up to 10 amps
  • Power supply current
Resources:
Digital Multimeter TECH Tips

Category Ratings

  • Category I: Usually electronic equipment or equipment where measures have been taken to limit transient over voltages.
  • Category II: Single phase loads like appliance personal computers, television sets, and other household loads. Outlets located more than 30 feet from a CAT III source or more than 60 feet from a CAT IV source.
  • Category III: Distribution level fixed installations like distribution panel devices, short branch and feeder circuits, three phase loads, and single phase commercial lighting.
  • Category IV: Equipment and lines located on the power line side of a service panel or where a low voltage connection is made to utility power.